Descargar Imprimir esta página

Hella FL Mini Instrucciones De Montaje página 15

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 23
EN
ENGLISH
Introduction:
Industrial trucks of highly varying types are in
use in large areas and in close quarters, in halls
as well as outdoor areas.
Applications:
Important:
This line of beacons is intended for applications
where the vehicles do not leave enclosed com-
pany grounds and are not used in street traffic.
15
e.g.:
• Fork lifts
• Sweeping and construction machines
• Distribution vehicles
Technical Data
Type approval:
ECE-R10 (E9) 10R-05 16200
SAE W3-3
UL-Certifi cation (USA)
Rated voltage
12 V / 24 V
Operating voltage
10-80 V (see page 11)
Power
approx. 8 W
consumption
Dome
PC
Operating position
Upright
Protective rating
IP67, IPX9K
Temperature range minus 40 ºC to plus 60 ºC
Inverse polarity
yes
protection

Publicidad

loading

Este manual también es adecuado para:

2xd 014 959-111