Emptying of the water tank
•
As soon as the water tank is full, the Watertank full indicator lights up, the standby mode automatically
turns on, it will sound the warning alarm and all the buttons will be locked until the tank is emptied.
•
Turn off the power and unplug the power
cord. To empty of the watertank you need
to remove the rubber stopper on the bottom
of the unit and let the water leak into a
container. Once you reboot the device, it
will work normally.
Continuous drainage (only in dehumidifying
•
mode): Remove the rubber stopper on the
bottom of the unit and connect the drainage
hose to the opening. Let the water leak into
a container (pic.4).
Cleaning
Always disconnect the appliance from the power outlet and let it cool before cleaning. Never immerse
•
the appliance in water to prevent electric shocks.
Wipe over the exterior of the appliance with a soft wet cloth and neutral detergent and then wipe dry
•
with a dry cloth.
Do not use gasoline or other chemicals to
•
clean the unit.
Clean the dust filter once every two weeks.
•
Clean the dust filter with neutral detergent
and about 40°C water. Rinse off any
detergent, then let it air-dry before inserting
it back into the unit (pic.5).
If you do not use the unit for a longer time,
•
empty the water tank completely. Make sure
that the unit is disconnected from the power
supply and that it is clean. Keep the unit
covered in a dry place.
Troubleshooting
Problem
1. Unit does not start
when pressing
"POWER".
2. It's not cool
enough.
Possible causes
Water tank is full and Waterfull indicator
is illuminated.
Room temperature is lower than the set
temperature during operation mode
cooling.
The ambient temperature is too low or
too high.
In dehumidification mode, the ambient
temperature is too low.
Doors or windows are not closed.
There are heat sources in the room.
Exhaust hose is not installed or blocked.
Set temperature is too high.
Air inlet is blocked.
Pic.4
Pic.5
Suggestions
Empty the water tank.
Reset the temperature.
We recommend the operaiton at 17-35°C.
The ambient temperature needs to be
higher than 17°C.
Close all doors and windows.
Remove the heat sources if possible.
Install the exhaust hose and make sure
that the hose is clean and not blocked by
any objects.
Reset the temperature.
Clean the air inlet