EON
2.1 PROTECTION FUNCTIONS
Protection functions can extend the life of the air conditioner and provide more comfortable airflow.
• Delayed start protection for the compressor
The compressor will start to work at least 3 minutes (5 minutes in heating mode) after it stops to maintain
the pressure balance of the refrigeration system.
• Observations
It will take 1 minute for the compressor to run after the unit is turned on for the first time.
• Defrost
The outdoor heat exchanger may freeze if the outdoor temperature is low and the humidity is high. In this
case, the automatic defrost will work for 3-10 minutes. the pause indicator will be on and the indoor and
outdoor fans will not work.
• HEAT overload protection (not available for cooling-only type of air conditioner) When the indoor pipe
temperature is too high, the air conditioner enters heating overload protection mode, and the indoor fan
speed should be set to a higher speed automatically. The outdoor fan and compressor can be stopped.
When the indoor pipe temperature drops to a nominal value, the air conditioner exits overload protection
mode. The indoor fan motor returns to its normal state.
• Residual heat function not available for refrigeration - refrigeration type only) The indoor fan keeps run-
ning at low speed for 80 seconds when the air conditioner stops in heating mode.
• Airflow Cooling Test (not available due to the raffreddamento - only of the type of conditioned air) In the
first minutes of heating operation, the PAUSE light will come on; the internal fan does not work and the
flaps cannot be controlled. Approximately 5 minutes later, the air conditioner emits a stream of hot air,
the PAUSE light is off.
• Avoid freezing
In order to prevent the indoor heat exchanger from freezing during cooling and drying, the compressor or
outdoor fan may stop working; the indoor fan speed will automatically adjust to a higher speed.
• Auto reset (optional)
The unit memorizes the operating mode, airflow setting, temperature setting, etc., so that if there is a
power outage when the unit is running, it will automatically return to the same operating condition when
it is restored energy.
• Anti drip
During cooling and dehumidifying operations, the louver flaps can automatically change position to
prevent dripping.
USER AND INSTALLATION MANUAL
2. PRODUCT PRESENTATION
47