USER AND INSTALLATION MANUAL
7. INSTALLATION
2. Connecting left back tube (similar to left lower tube). (optional, Refer to Fig. 9)
• Move the discharge tube to the left side, and discharge cap to the right side.
• Fix the tubes in the slot of the indoor unit with the fix clamp.
• The following mounting steps are the same as those in "1. Connecting right back tube."
Notes:
Left chart is available for the position of drain hose,refer to Fig 7.
Right chart is available for the position of drain hose,refer to Fig 9.
Rightward
Downward
7.8 OUTDOOR UNIT INSTALLATION
• If installation brackets for installing outdoor unit are needed, user could buy the brackets from our com-
pany or agents (Fig.10)
• Assemble the mounting frame and supports with the attached 6 screws ( M12x25), plain washers, spring
washers, and nuts.
• Drill 4 or more holes on the wall according to the feet size of the air conditioner. Determine the locations
for mounting left and right supports. Ensure that the left and right supports are on the same level.
• Fix installation frame on the wall with expansive bolts.
• Fix outdoor unit with 4 bolts (M10x25) on the installation brackets.
• Fittings must be tightly screwed; Connection must be tight and reliable.
• In installing outdoor unit, the body should be hung with ropes to prevent from falling.
64
Leftward
De vuelta
Drain hole
Drain
hole
Installation
board
Fig.7
Fig.9
SPLIT 1X1
EON
Wall
Left
back
Fig.8