Descargar Imprimir esta página

HTW EON -S026EON-R32 Manual De Usuario E Instalacion página 60

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

USER AND INSTALLATION MANUAL
7. INSTALLATION
7.2 INSTALLATION GUIDE
• This air conditioner meets the safety and operation standards promulgated by the Nation.
• You need to invite professional air conditioner service and maintenance personnel to install or remove
the air conditioner. Problems may occur and you may suffer losses if non- professionals install the air
conditioner.
• User shall provide the power that meets installation and operation requirements. please refer to name-
plate for details about the voltage for this product. Voltage beyond this scope will affect the normalope-
ration of the air conditioner.
• Separate power point with delay fuse protector or automatic breaker should be used for the airconditioner.
• The air conditioner must be correctly and reliably grounded, or it may cause electric shock or fire.
• Do not switch on the power of the air conditioner before well connecting and carefully checking the tu-
bing and wires.
• The appliance shall not be installed in laundry or bathroom.
• In case necessary, please consult your supply authority for system information.
• The plug shall be accessible after installed the appliance.
• This instruction is subject to change without notice.
Installation of Accessories
• Examine carefully the attached packing list and check whether the accessories are complete.
• Users may need to buy at their own expenses the articles not included in the packing list and may be
needed in installing.
7.3 POSITION FOR INDOOR UNIT
• Away from the place where there is heat source, steam source, leakage of flammable gas and smoke.
• No obstacles near the inlet and outlet, and keep good ventilation.
• Good discharge for water.
• At least 1m away from wireless equipment (such as
TV, radio etc.).
• Mounted on the wall that can bear the weight of the air
conditioner and won't produce noise while unit working.
• The distance between the indoor unit and the floor
should be greater than 2.3m.
• The plug shall be accessible after installing the
appliance.
• Ensure the distance as required in Fig.1.
• The back of the indoor unit should be close to the wall
(Fig.1)
• The all figures are only schematic, and they may be slightly different from the actual appliances you
selected.
60
SPLIT 1X1
EON
At least 15cm
Fig.1

Publicidad

loading

Este manual también es adecuado para:

Eon htw-s035eon-r32Eon htw-s052eon-r32