SPLIT 1X1
EON
Attachment: Installation instructions for decorative cover plate
Outlet
Step 1: Wrap PVC protective tape around drainage pipe,copper pipe
and cable.Adjust the copper pipe tube to a suitable shape.
Note:
The above diagram may be difference from the actual product, please refer to the actual product.
7.7 INDOOR UNIT INSTALLATION
The tube may be connected in several directions as below shown Figures.
1. Connecting right back tube (similar to right lower tube) (optional, Refer to
Fig.6)
• Pull out the tubing from bottom of the chassis; and connect the drainpipe.
Strap the joint of tubing reliably.
• Lead the connecting wire to the indoor unit (Do not connect to the power).
• Strap together the tubes, discharge pipe and connecting wire with adhesive
tape. The discharge pipe is put at the below. Remove the board which is on
the chassis.
• Check if the connections are reliable.
• Mount the indoor unit on the two hooks at the upper part of installation board.
(Refer to Fig.8)
Cover plate
Step 2: Install the cover plate.
Step 3: Finish
USER AND INSTALLATION MANUAL
7. INSTALLATION
Connecting
Drain pipe
wires
Pipeline
Fig.6
63