Model 37010-Series / Conversion Kits
FEATURES
• High Capacity Macerator and Bowl Scavenger Pump
• Flexible Impeller Flush Pump
• Permanent Magnet Type Motor, Fully Enclosed, with Stainless
Steel Shaft
• Complies with USCG 183.410 and ISO 8846 MARINE for
Ignition Protection
• Simple Push Button Switch included
• All Corrosion Resistant Materials for Marine Use
SPECIFICATIONS
• 5/8" (16mm) or 3/4" (19mm) Inlet, 1" (25mm) Outlet Back
Flow Check Valve in Discharge
• 1"x 1-1/2" (25mm to 38mm) Hose Adaptor included to adapt
to 1-1/2" (38mm) waste plumbing.
• Thru Flow Approx. 1-1/2 Qts. (1.4 Liters) per 5 Seconds of
Operation
VARIATIONS
MODEL NO.
37010-0092
37010-0097
APPLICATION
The Jabsco electric toilet may be installed above or below the
waterline. Flush pump is self-priming with a vertical lift up to 4
feet (1.2m); discharge macerator pump can operate against a
vertical head up to 4 feet (1.2m).
The 37010 series can be used to convert the Raritan PH or
Compact, Wilcox-Crittenden "Head Mate", Groco HC, Brydon No.
9127, 9128, or No. 59128 and virtually any other model marine
toilet using the "standard" bowl configuration with a 3-3/4"
(9.5cm) diameter bolt circle, 4 hole pattern in the base. Check
the dimensional drawing to be sure the bowl will fit the flange
dimensions as shown.
The 37010 series includes the complete motorized base assembly,
bowl gasket, four bolts and washers for bowl, two 5/8" (16mm)
to 3/4" (19mm) pump port adaptors, 3/4" (19mm) white hose, 1"
(25mm) to 1-1/2" (38mm) discharge port adaptor, and momen-
tary control switch.
ASSEMBLY
1. Overall height after conversion may increase up to 1" (25mm)
on some models, check to be sure adequate space is available
if located under seats or bunks.
2. Screw 6mm machine screws with starlock washer under each
head into nuts positioned in the hex recess on the top of the
base to form bowl attachment studs (see exploded view).
3. Remove complete manual base assembly and mount bowl on
Jabsco motorized base. NOTE: M6 x 2" (50mm) long machine
DESCRIPTION
Toilet Conversion, 12 Volt
Toilet Conversion, 24 Volt
screws supplied are suitable for most bowls; however some
bowl flanges are heavier and longer machine screws must be
used. Place plastic washers against bowl flange, positioning
base for most convenient hose connection arrangement.
4. Connect pump outlet to rear bowl connection with 3/4"
(19mm) hose. Install the hose clamp on the pump discharge
port only.
5. Position complete toilet assembly and fasten securely on flat
surface. Be sure not to warp toilet base when tightening toilet
base down.
6. Connect existing inlet hose to pump inlet port. A 5/8" (16mm)
to 3/4" (19mm) sleeve adaptor is included for fitting to
commonly used 3/4" (19mm) inlet hose size. Make sure all
connections are airtight and free of sharp bends or restrictions.
7. Connect 1" (25mm) discharge hose to discharge port (1-1/2"
(38mm) hose when using 1-1/2" (38mm) discharge adaptor)
and make suitable connection to holding tank or other
discharge system. Avoid sharp bends or restrictions.
8. For installation below the waterline, install a vented loop
with solenoid valve in the intake hose and position about 8"
(20cm) above the waterline at all angles of heel or trim. *A
vented loop should also be used for discharge if connected to
a thru-hull fitting.
9. For installations above water line, make a loop in discharge
line about 8" (20cm) above base of bowl to retain water in
bowl. Some installations may need a check valve in the intake
line to aid primeability of flush water pump.
10. If thru-hull seacocks cannot be conveniently operated from
toilet location, install suitable shut-off valves for inlet and
discharge connections.
*It In some installations when a vented loop is installed in the intake hose,
the flushing pump primeability and flow charac-teristics are reduced and
may adversely affect toilet function. To restore pump performance, connect a
solenoid valve (Jabsco No. 37068-2000) to the vent air inlet to interrupt the
air supply during the flush cycle. The brass port of the solenoid valve (remove
plastic filter if attached) should be connected to the vent inlet with 3/16"
(4.76 mm) hose and the solenoid wired in parallel with the toilet motor. See
Diagram 1 for installation and wiring illustration.
2