Descargar Imprimir esta página

Xylem JABSCO 37010 Serie Manual De Instrucciones página 5

Kit de base de inodoro eléctrico/ kits de conversión
Ocultar thumbs Ver también para JABSCO 37010 Serie:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 20
DIAGRAM 1
MOUNTING
BRACKET
VENT TO
ATMOSPHERE
37068-2000
ELECTRICAL
CONNECTIONS
REASSEMBLY INSTRUCTIONS
Press seal into body with lip facing impeller, be careful not to cock
seal in bore. Install pump body on motor and position on register;
lubricate impeller bore with pump grease. Install impeller, gasket
and wearplate. Make sure gasket surfaces are clean and smooth.
Tighten wearplate screws. Slide shaft sealing sleeve onto shaft and
seat in its bore in wearplate. Relocate centrifugal impeller about
1/8" from wearplate and secure with set screw.
DIMENSIONAL DRAWING Inches (Millimetres)
DESSIN DIMENSIONNEL Pouces (Millimètres) / MAßZEICHNUNG Zoll (Millimeter)
DISEGNO DIMENSIONALE Pollici (millimetri) / MAATTEKENING Inch (Millimeter)
DIMENSIONELL RITNING tum (millimeter) / DIBUJO DIMENSIONAL Pulgadas (milímetros)
3.12 [78.7]
3.12 [78.7]
7.125 [181]
6.2 [157.4]
COUVERCLE MOTEUR / MOTORABDECKUNG / COPERTURA MOTORE / MOTORKAP / MOTORKÅP / CUBIERTA DEL MOTOR
VIEW A
TO VENTED
LOOP
3.7 [93.9]
14.0 [355.3]
3 x HOLE FOR 1/4 OR 6mm SCREW
MOTOR COVER
TO
NEGATIVE
TO
POSITIVE
PUSH BUTTON
TO
NEGATIVE
DISCHARGE TO
HOLDING TANK
Position macerator housing around centrifugal impeller then put
chopper plate on end of shaft and secure with lock nut. Install
0-ring in 0-ring groove in wearplate surface (a little grease will
help hold in place). Aligning key on top of macerator housing with
slot in base, slide macerator assembly into base. Secure pump
assembly with the four screws.
14 GA, 12.00 LONG
ORANGE (+)
BLACK (−)
5
VIEW A
SWITCH
3.8 [96.4]
1.7 [4.31]
4.8 [121.8]
WATER
LINE
INLET

Publicidad

loading

Este manual también es adecuado para:

Jabsco 37010-0092Jabsco 37010-0097