Never use an extension cord
Your Friedrich Room Air Conditioner is equipped with a
three-prong (grounded) plug tbr your protection against shock
hazards and should he plugged directly into a properly grounded
three-prong receptacle. If you have a two-prong receptacle you
will need to have the circuit replaced by a certified electrician
with a grounded circuit that meets all national and local codes
and ordinances. Under no circumstances should you remove
the ground prong from the plug. You must use the three-prong
plug furnished with the air conditioner.
NEVER CUT OR REMOVE THE GROUNDING
PRONG FROM THE PLUG.
--Test Button
ResetButton
Figure
7
Power cord information
All Friedrich room air conditioners
are shipped from the
factory with a Leakage Currant Detection Interrupter (LCDI)
equipped power cord. The LCDI device meets the UL and
NEC requirements lbr cord con uected air conditioners effective
August 2004.
To test your power supply cord:
1. Plug power supply cord into a grounded 3 prong outlet.
2. Press RESET (See Figure 7).
3. Press TEST (listen tBr click; Reset button trips and pops
out).
4. Press and release RESET (listen t_r click; Reset button
latches and remains in). The power supply cord is ready
lbr operation.
NOTE: LCDI device is not intended to be used as a switch.
Once plugged in the unit will operate uorlnally without the
need to reset the LCDI device.
If the device fails to trip when tested or if the power mpply cord
is damaged it must be replaced with a new supply cord from
the manufacturer. We recommend you contact our Technical
Assistance
Line at (800) 541-6645 ext. 662. To expedite
service, please have your model and serial number available.