Status
All LEDs show in sequence, followed by one (1)
LED showing constantly red.
4
Technical data
4.1
Product information
Rated voltage
Weight in accordance with EPTA Procedure 01, without battery
Output power (separately)
Output power (totally)
Storage temperature
Ambient temperature for operation
4.2
Wireless information
Wireless power transfer frequency
Maximum H-field strength
4.3
Battery
Battery operating voltage
Weight, battery
Ambient temperature for operation
Storage temperature
Battery charging starting temperature
5
Preparations at the workplace
WARNING
Risk of injury by inadvertent starting!
▶ Remove the battery before making adjustments to the product, changing accessories, or putting the
product away.
Observe the safety instructions and warnings in this documentation and on the product.
5.1
Charging the battery
1. Before charging the battery, read the operating instructions for the charger.
2. Make sure that the contacts on the battery and the contacts on the charger are clean and dry.
3. Use an approved charger to charge the battery. → page 17
*2401892*
Meaning
If a connected product can still be used, the re-
maining battery capacity is below 50 %.
If a connected product can no longer be used, the
battery has reached the end of its useful life and
has to be replaced. Consult Hilti Service.
USB-A
USB-C
Wireless
USB-A + USB-C + Wireless
115 kHz ... 148 kHz
5.2 dBuA/m (@10m)
2401892
21.6 V
260 g
(9.17 oz)
5V/3A, 9V/2A, 12V/1.5A (≤18 W)
5V/3A, 9V/3A, 12V/3A, 15V/3A,
20V/3.25A (≤65 W)
≤10 W
≤ 93 W
−20 ℃ ... 60 ℃
(−4.0 ℉ ... 140.0 ℉)
−17 ℃ ... 40 ℃
(1.4 ℉ ... 104.0 ℉)
21.6 V
See the section headed "Intend-
ed use"
−17 ℃ ... 60 ℃
(1.4 ℉ ... 140.0 ℉)
−20 ℃ ... 40 ℃
(−4.0 ℉ ... 104.0 ℉)
−10 ℃ ... 45 ℃
(14.0 ℉ ... 113.0 ℉)
English
19