Remove reel of Tiewire
When you have finished the Tiewire, remove the
reel from the tool.
Store the tool
When you have finished tying work or when the
tool will not be used for a while, set the Main
switch (Fig.1.f) at "OFF", the Trigger lock
(Fig.1.2) at "LOCK" and remove the Battery pack
(Fig.1.5). The tool and accessories should be
stored in a well-ventilated dry place where the
temperature will not exceed 40°C (104°F).
The Battery pack with the Pack cap (Fig.2.o) to
prevent short circuits should be stored in a well-
ventilated dry place where the temperature will
not exceed 30°C (86°F).
Maintenance
Do not blow air around Feeding gears (Fig.1.k)
and Hooks (Fig.1.g).
Dust can enter the inside of a machine and
cause malfunctions.
When three short beeps are repeated, dust the
sides of sensors (Fig.35.t) and the top of
lenses (Fig.35.u) with a soft cloth or cotton bud
gently.
Wipe the tool with a soft dry cloth.
Do not use a wet cloth or volatile substances
such as thinner or benzine.
Do not lubricate the equipment.
Absolutely do not lubricate this equipment.
Applying lubrication will remove the grease
inside of the tool, and cause problem on the tool.
How to open and close the window
The Window (Fig.36.j) at the front of the tying
tool is secured by Hex bolt (Fig.36.m).
If foreign objects enter or wires become
entangled, loosen the bolt with Hex wrench (Hex
key) (Fig.36.x), open the window, and remove
the cause of the malfunction.
Secure it with 0.75N•m (7.5kgf•cm) torque.
• You can check the video about operation
and maintenance from the link below.
https://play.dooonut-pf.com/#/
2f8r2wd7m8zet?oid=574&sid=2
20