Descargar Imprimir esta página

Cinderella JUBILEE EM03CS10 Manual Del Usuario página 10

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 183
NOTE!
The pipe must always be installed vertically above the
roof and extend at least 600 mm above the roof surface.
If the outlet air pipe is to be enclosed (e.g. using metal
siding), make sure that the end of the pipe extends at
least 400 mm above the enclosure.
If installed where snow is likely to accumulate it might be
necessary to extend the pipe further, and to secure ac-
cordingly. Keep in mind not to extend beyond maximum
allowed pipe length.
2.5.2 INSTALLING THE HORIZONTAL INLET PIPE
It is important to ensure that the toilet has enough access to fresh air, and we therefore always recommend
installing the Cinderella Jubilee with designated inlet air connection. Supplying fresh air from the outside and
into the appliance is essential for cooling, circulation and the supply of oxygen to the incineration process. If the
toilet has restricted access to air/oxygen, you will experience poor incineration, reduced efficiency and possibly
overheating of the appliance. Poor incineration over time will wear on the product and void your warranty.
OUTER DIAMETER
INLET PIPE
110 mm
Ø 111mm
155mm
35 mm
35 mm
40 mm
!
40 mm
10
INNER DIAMETER
INLET PIPE
102 mm
INLET
DIRECTION
Horizontal
NOTE!
The center hight for the inlet air terminal is
155 mm from the floor level.
The Original Cinderella Installation kit in-
cludes 2 x 500 mm pipes to be utilized for the
inlet air and ventilation and flue terminal cap.
Adjust the length of inlet to fit he installation,
please notice that the pipe will enter 40 mm
into the inlet terminal on the appliance.
NOTE!
When mounting the storm collar on the external
wall, make sure that the bottom of the pipe is
installed flush with the bottom of the storm collar.
Misplacement will lead to restricted air circulation
that cause poor incineration, reduced efficiency
and possibly overheating of the appliance.
NOTE!
Cinderella supplies a specially designed
"siphon" that fits onto the elbow provided in
the installation kit, this item can be purchased
as an accessory from any Cinderella dealer. If
installation is done from the interior, you will
need to connect the siphon to the elbow-piece to
prevent condensation and rainwater to drain onto
the floor. Failure to collect the condensation and
emptying it regularly, may result in damage to the
floor.
MAXIMUM
PIPE LENGTH
500 mm

Publicidad

loading