4.2.6 RINSING THE CATALYTIC CONVERTER WITH HOT WATER
Recommended frequency: at least every 500 uses.
Rinsing the catalytic converter with water may be necessary in situations where steam cleaning do not remove
the particles or bad odours. This procedure requires heavy lifting and a facility where spillage of water is
acceptable. Make sure to perform steps 1.-4. in the "Cleaning the appliance flue terminal" (section 4.2.5)
procedure and follow the steps as follows.
1. Place the toilet where it is OK to spill water, e.g.
where there is a suitable drain, outside or in a
bath. Use the specially designed Cinderella funnel,
or a funnel that fits in the flue terminal. Tilt the
toilet forward, and pour 2–3 L of hot water through
the flue terminal and catalytic converter. The
excess water should be clean at the end of the
rinsing process. If necessary, use more water to
properly clean the system.
2. Repeat step 1 4-5 times until the water is clean and
no crystals or other obstructions can be spotted
when inspecting the catalytic converter (see
section 4.2.4)
3. Reconnect the appliance to the flue pipe and
power supply.
4. Install the ash container and front cover.
5. Perform the performance test as described in
section 2.8
NOTE!
Before disconnecting the appliance and rinsing the system with hot water, inspect the
catalytic converter and perform steam cleaning in accordance with section 4.2.2. If the
catalytic converter is still clogged, or odour is still noticeable when incinerating, perform the
rinsing as described above
CAUTION!
The front of the outer shell is thin and should therefore not carry the entire weight of the
toilet. Be gentle while tilting the appliance and make sure that the toilet is placed in such a
position that the toilet shell is safeguarded. It is advised to be two people to do this operation,
where one can hold the toilet while the other rinses the catlytic converter.
5. TROUBLESHOOTING AND FAQ
WARNING!
Service must be performed in accordance with all state, municipal and local codes. If
you are unsure of the regulations in your area, please contact your nearest dealer or
service representative for further instructions. The power should be disconnected when
performing all servicing and maintenance on the toilet.
Online Troubleshooter Module
If the toilet encounters any problems during operation, it will display a warning code or error code as described
under "Warning & Error messages" on the next page. We have gathered the most common errors / problems
in an online troubleshooter, so that you can easily get answers to what is wrong with your toilet, and get
suggestions on how you can solve the problem yourself.
24