CODE
ERROR
E10
Heating circuit error
E11
Temperature sensor error
E12
Temperature in toilet shell too high
E13
Vent fan is not working as intended
E15
E16
Hatch error
E17
E22
230V main power is not detected.
E24
Failed to open front lid.
E25
Shell temperature sensor error
NOTE!
There may be errors not listed here displayed on your toilet. If this happens, try to reset the
toilet, if this does not fix the issue, contact a service provider and inform them of your error
code for further assistance.
REQUIRED ACTION
1. Make sure installation is in accordance to
specification.
2. Reset the bi-metal thermostat as shown in section 5
3. Reset the toilet as described in section 5
4. If error persist contact a service provider.
1. Reset the toilet as described in section 5.
2. If error persists, contact a service provider.
1. Make sure installation is in accordance to
specification, that airflow is unobstructed.
2. Reset the toilet as described in section 5.
3. If error persist contact a service provider.
1. Reset the toilet as described in section 5.
2. If error persist contact a service provider.
1. Open and close lid so that the "Start" button becomes
green, then press it to make another deposit.
2. If unsuccessful, reset toilet, insert a bowl liner and
pour 3 cups of water into the liner, close lid and press
"Start"
3. If unsuccessful wait until the toilet has cooled (fan
stopped), restart toilet and use the "unjam hatch" option
in the service menu, then check for and remove stuck
items manually.
4. If error persists, contact a service provider.
1. Make sure the toilet is connected to a power source in
accordance with section 2.6.
2. If error persists, contact the service department
1. Make sure there is nothing obstructing the front lid
from ejecting.
2. Check if the front lid is loose by pulling gently on it.
3. Try removing the front lid manually as described in
section 3.8.1.
4. If problem persists contact a service provider.
1. Reset the toilet as described in section 5.
2. If error persists, contact a service provider.