OPERATION
High voltages capable of causing severe injury or death by electrical
shock are present in this unit.
Connect this pump to a circuit equipped with a ground fault circuit interrupter (GFCI) device if required by code.
This product is supplied with a grounding conductor and grounding-type attachment plug. To reduce risk of electric shock, be
certain that it is connected only to a properly grounded grounding-type receptacle. Do not remove the third prong from the plug.
The third prong is to ground the pump to help prevent possible electric shock hazard.
Risk of damage to pump or other equipment.
Do not let the unit run dry (without liquid). It is designed to be cooled by pumping fluid. The seal may be damaged and the motor
may fail if the pump is allowed to run dry.
1. Plug the power cord directly into an electrical outlet.
IMPORTANT: Check the pump label for proper voltage required. Do not connect
to voltage other than that shown.
2. Unplug the unit as soon as the pump stops pumping water or the suction sound
changes to prevent the pump from running dry.
3. If the pump does not operate properly, refer to
MAINTENANCE
Risk of severe injury or death by electrical shock, high temperatures, or
pressurized fluids.
Always unplug the pump power cord in addition to removing the fuse or shutting off the circuit breaker before working on the
pump or switch.
Let pump cool for a minimum of 2 hours before attempting to service. Submersible pumps can become pressurized and hot
under normal operating conditions.
Risk of damage to pump or other equipment.
This unit is permanently lubricated. Oiling is not required. Do not open the sealed portion of the unit or remove housing screws.
Do not remove the motor housing cover.
Do not remove the impeller. This action requires special tools and may damage the pump.
Warranty is void if the motor housing cover or power cord have been removed.
Periodic Service
IMPORTANT: If the power cord is damaged, the whole unit must be replaced.
1. After unplugging the pump from electric power, disconnect the discharge
hoses from the pump.
2. Remove the screws (1) that hold the thermoplastic base (2) and volute plate
(3) to the volute housing.
3. Remove the base and volute plate.
IMPORTANT: Do not remove the impeller.
"Troubleshooting" on page
OPERATION
Periodic Service
4.
3
2
1
3