MAINTENANCE
Troubleshooting
4. Clean the impeller and the volute passage.
IMPORTANT: Do not use strong solvents on the impeller.
5. Be sure the impeller turns freely after cleaning.
6. Replace the volute plate and base and secure with screws.
Troubleshooting
Problem
Pump does not turn on
Pump runs but does not
discharge fluid
Pump does not deliver
rated capacity
Pump restarts unexpect-
edly (Tripped overload)
Replacement Parts and Accessories
Part
1
Discharge/Adapter Kit contains 3/4" discharge, seals, hardware and 1-1/4" FNPT adapter
2
SA-1 Sacrifical Anode (Optional accessory)
3
Universal 24' Hose Kit with 1-1/4" and 1-1/2 adapters (Optional accessory)
4
Vertical float switch with 10' cord (Optional accessory)
5
Tethered float switch with 10' cord (Optional accessory)
For technical assistance, parts, or repair, please contact:
800.701.7894 | littlegiant.com
10000016006 Rev. 001 06/23
Probable Causes
Pump not plugged in
Circuit breaker off or fuse removed
Corroded power cord plug prongs
Tripped overload
Defective motor
Blocked or jammed impeller
Suction lift is too high
Inlet to impeller plugged
Lift too high for pump
Partially blocked inlet
Impeller or discharge pipe is clogged
Impeller wear due to abrasives
Blocked or jammed impeller
Pump running dry
Pump air-locked
Excessively high or low voltage supply
1
5
Description
Connect pump power cord to a GFCI circuit.
Turn on circuit breaker or replace fuse.
Clean prongs on power cord plug.
Allow pump to cool, investigate cause (i.e. jammed impeller).
Replace pump.
Clean impeller; refer to
Reduce the pump height to water source.
Pull pump and clean, refer to
Check rated pump performance.
Clean inlet.
Pull pump and clean. Check hose for kinks or blockage.
Replace pump.
Pull pump and clean, refer to
Turn off pump.
Check the pump label for proper voltage required. Do not
connect to voltage other than that shown.
3
2
4
Corrective Action
"Periodic Service" on page
"Periodic Service" on page 3
"Periodic Service" on page 3
Order Number
14942729
599002
Franklin Electric Co., Inc. | Oklahoma City, OK 73157-2010
Copyright © 2023, Franklin Electric, Co., Inc. All rights reserved.
3.
599303
599261
599118