The ID is required when, for example, the activation codes are to be
entered.
If the rotary switch (Pos. 7) is pressed for longer than 10 seconds, the
following appears on the digital LED display (Pos. 6):
[SOFTWAREVERSION_DEVICETYPE]. For example, if [1_20] is displayed =
Softwareversion 1 _ Devicetype 20
6.2.4 Automatic start/stop/external on/off
Automatic start/stop
As soon as the start/stop module (optional) is connected to the connection
socket (Pos. 3), the product switches off and automatically switches to
start/stop mode. In start/stop mode, the LED signal lamp (Pos. 5) flashes
green.
When the start/stop module is activated by a welding process, the product
starts. After the welding process is finished, the product switches off again
after an adjustable run-on time. (preset run-on time 30 seconds)
During operation, the product can be switched off at any time by pressing
the rotary switch (Pos. 7).
On/Off via extraction hood
There is a socket on the connecting piece of the extraction hood to switch
the product on and off using a switch on the extraction hood. This signal
has the same status as the on/off function of the rotary knob (Pos. 7).
On/Off via 4-pin connection socket
Either a start/stop sensor or a potential-free contact can be connected to
the 4-pin connection socket on the rear of the product. This socket is
connected in parallel to the connection socket for connecting the
extraction hood.
6.2.5 Warning – Insufficient extraction capacity
If the required extraction capacity is not achieved, a warning signal sounds
after 5 minutes and [A 0 5] appears on the digital display (Pos 6). The LED
signal light (Pos. 5) flashes in magenta during this message.
6.2.6 Cleaning the filter cartridge
A contaminated filter cartridge causes an increased differential pressure.
If a differential pressure of more than 1500 Pa occurs on the filter cartridge,
cleaning of the filter cartridge is automatically triggered.