DC current
WARNING! Risk of electric shock,
never measure current where
open circuit voltages exceed
250 V to prevent damage to the
meter or personal injury.
• Insert the black test lead into the
COM jack.
• Turn the rotary switch to the
mA 
• The default mode is DC current.
Press "RAN" to switch to manual
range if needed.
• Connect the test probe and test
lead in series with the circuit
under measurement.
• The display will show the
measured value. Observe the
polarity of the test probe for DC
current measurements.
NOTE:
• "OL" indicated an over-range
situation in manual mode.
A higher range should be
selected.
87_5059340213873_BODNER_A6_IM_MULTI_V03.indd 27
87_5059340213873_BODNER_A6_IM_MULTI_V03.indd 27
EN Use
position.
AC current
WARNING! Risk of electric shock,
never measure current where
open circuit voltages exceed
250 V to prevent damage to the
meter or personal injury.
• Insert the black test lead into the
COM jack.
• Turn the rotary switch to the
mA  position.
• The default mode is DC current.
Press "FUNC" to switch to
AC current. Press "RAN" to
switch to manual range if needed.
• Connect the test probe and test
lead in series with the circuit
under measurement.
• The display will show the
measured value. Observe the
polarity of the test probe for
DC current measurements.
NOTE:
• "OL" indicated an over-range
situation in manual mode.
A higher range should be
selected.