Descargar Imprimir esta página

cecotec SPRINT Manual De Instrucciones página 86

Bicicleta eléctrica

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 66
ENGLISH
: voltage
: brake failure
: motor failure
: accelerator failure
: wheel diameter
: headlight
: controller failure
Buttons
6. Increase
7. Power/mode
8. Decrease
Parameters
P01: Display brightness (level 1 is the darkest and level 3 the brightest).
-
-
P02: Mileage unit, 0: KM; 1: MILE
-
P03: Voltage level: 24 V, 36 V, 48 V, 60 V, 64 V.
P04: Latency time. 0 indicates no latency. Any other number indicates latency time. Range:
-
1-60 (minutes).
-
P06: Wheel diameter (inches). Precision: 0.1. This parameter is related to the speed
displayed on the console.
Note: The unit used is kilometres. When changing from kilometres to miles, the speed shown
will be in miles. However, the speed limit will not be changed to miles.
Note: Programmes P09-P15 are only valid in communication status.
-
P09: Zero (and non-zero) start. 0 indicates zero start; 1 indicates other non-zero starts.
-
P11: Pedal fluidity range: 1-24.
P12: 0-5 gears.
-
-
P14: The limit value of the controller is set to 12 A by default. Range: 1-20 A.
P15: Controller voltage setting.
-
P16: ODO. To set the value to zero, press and hold the button for five seconds.
-
-
P17: Cruising speed. A value of 0 means that it is not allowed to activate the cruising speed.
When activated, 1 will be displayed.
-
P18: Adjusting the size of the speed on the display (50%~150%).
-
P19: Assistance mode. If the number displayed in the assistance mode is 0, it means that
assistance is not activated. 1 means that assistance is activated.