3.2. First commissioning
When first powering on the electronic unit:
1) Carry out the programming below.
Successive
menus
2) The
3) Some successive security measures are displayed while the cell fills completely.
3.3. Indicators
Colour
Green
Red
3.4. Screen
If the display is flashing: Information awaiting validation, or alarm triggered.
If display steady: Confirmed information or in read only.
DEFAULT DISPLAY
Settings
MODEL
via the
Inline display
DUO
PRO (1)
Dashboard
Possible settings
French
English
Deutsch
Español
Italiano
Nederlander
Portugués
From 10 to 200m3, in increments
of 10m3
Day/Month/Year
Hour/Minute
In-line
Dashboard
Status
Continuously on
Continuously on
Flashing
Overview
For each menu, select a setting with the
then confirm with the OK button.
Production in progress
Electronics unit powered off
Alert activated
Alarm activated
Production setpoint
(additional indicator on the green LED).
pH measurement
Production setpoint
displayed
when
production is in operation
(indicator in addition to the
green light).
pH measurement
Navigation
Possible meanings
MEANING
appears when production is running
the
Salt level
Water temperature
buttons,