Operation with a cover sensor:
It is impossible to start Boost mode when the cover is closed.
If the cover closes with Boost mode activated, Boost mode stops instantly.
Menu
Possible settings
3.7.18. Setting the ORP setpoint
Menu
From 200 to 900 mV, in increments of 10.
3.7.19. Calibrating the ORP probe
The ORP probe originally supplied is already calibrated. As a result, it is not necessary to perform a calibration
when putting the equipment into service for the first time.
1) Open the 475 mV ORP standard solution.
2) Turn off the filtration (and therefore the electronics unit).
3) If the probe is already installed:
a) Remove the probe from the probe holder, without disconnecting it.
b) Remove the probe holder nut and replace it with the stopper supplied.
If the probe is not already installed:
Connect the probe to the electronics unit.
4) Turn on the electronic unit.
5)
6) Follow the instructions below:
OK
OK
(Wait a few seconds)
or
Default setting
12 hrs
24 hrs
24 hrs
Possible settings
Insert the probe into the ORP calibration solution, then wait 5 minutes.
Do not touch the probe.
a) Rinse the probe under running water, then leave it to drip-dry without wiping it.
b) Install the probe into the probe holder.
Perform the navigation again with the above instructions, several times if necessary.
If the calibration still fails, replace the probe and perform a new calibration.
Switching on
Automatic, as soon as the selected
setting is confirmed, with a delay of
a few moments
Switching off
Press
Default setting
670 mV