b. Fill a container with an acid solution.
c. Immerse the electrode in this container, keeping the connectors out of the liquid.
d. Rinse the electrode in fresh water.
e. If the inner wall of the cell sleeve is scaled, remove this scale manually (without tools)
13) Replace the cell by tightening the power cable nuts (3 N.m).
14) Check the condition of the transparent chlorine evacuation hose. If this shows traces of limescale, replace it
with a new pipe.
15) Close the water inlet valve.
16) Drain the brine tank.
17) Clean and rinse the pH and ORP probes in fresh water and store for winter.
18) Store the probes in the storage containers, positioning them vertically with the bulb at the bottom.
NEVER TOUCH OR WIPE THE PROBE BULB. NEVER KEEP THE PROBE IN DISTILLED WATER.
4.3. Bringing the apparatus out from overwintering
1) Replace the probes in the accessory holder.
2) Place salt in the reactor.
3) Open the water inlet valve and wait until the system stops filling.
4) Allow the salt to dissolve for 1 hour.
5)
6)
, perform a manual brine injection for 6 minutes.
.