Motor Specifications and Electrical Requirements

General Specifications

General Specifications
Band saw
Partnumber
Power
127V
220V
Frequency
Voltage Rating
127V
220V
No Load Speed
Throat
Blade
Cutting Capacity
Protection security
Table size
Peso conforme EPTA 01/2003
Motor Specifications
In the event of a malfunction or breakdown, grounding
provides a path of least resistance for electric current to
reduce the risk of electric shock. This tool is equipped with
an electric cord having an equipment-grounding conductor
and a grounding plug. The plug must be plugged into a
matching outlet that is properly installed and grounded in
accordance with all local codes and ordinances.
Before connecting the motor cord to power source,
make certain the switch is in the "OFF" position and be
sure the electric current is of the same characteristics
as stamped on the band saw nameplate.

Connection To A Power Source

This machine must be grounded while in use to protect
the operator from electric shock.
Plug power cord into a properly grounded type outlet
protected by a 15-amp dual element time delay fuse or
circuit breaker.
Not all outlets are properly grounded. If you are not
sure that your outlet, is properly grounded; have it
checked by a qualified electrician.
To avoid electric shock, do not touch
DANGER
!
the metal prongs on the plug when
installing or removing the plug to or from the outlet.
Failure to properly ground this power
!
DANGER
tool can cause electrocution or
serious shock, particularly when used near metal
plumbing or other metal objects. If shocked, your
reaction could cause your hands to hit the tool.
If power cord is worn, cut or damaged
!
WARNING
in any way, have it replaced
immediately to avoid shock or fire hazard.
3:00 PM
Page 5
F 012 338 5..
[w]
[w]
250 (60HZ)
220 (50HZ)
[HZ]
[A]
[A]
1,27 (60HZ)
1,17 (50HZ)
[/min]
1650 (60HZ)
1360 (50HZ)
[mm]
[mm]
[mm]
300 x 300
If the outlet you are planning to use for this power tool is
of the two-prong type, DO NOT REMOVE OR ALTER
THE GROUNDING PRONG IN ANY MANNER. Have a
3385
qualified electrician replace the TWO-prong outlet with a
properly grounded THREE-prong outlet.
270
Improper connection of the equipment-grounding
conductor can result in a risk of electric shock. The
conductor with insulation having an outer surface that is
50 / 60
green with or without yellow stripes is the equipment-
2.2
conductor. If repair or replacement of the electric cord or
plug is necessary, do not connect the equipment-
grounding conductor to a live terminal.
Check with a qualified electrician or service personnel if
the grounding instructions are not completely
229
understood, or if in doubt as to whether the tool is
properly grounded.
1510
89
Always use proper extension cord. The use of any
/ I
extension cord will cause some loss of power. To keep
this to a minimum and to prevent overheating and motor
burn-out, use the table below to determine the minimum
15,2kg
wire size (mm²) extension cord. Use only 3-wire
extension cords which have 3-prong grounding type
plugs and 3-pole receptacles which accept the tool's
plug. Make sure your extension cord is in good
condition.
Extension Cord Length
0-7620mm ...................................................... 1.31 mm²
7924.8-15240mm ......................................... 0.823 mm²
15544.8-30480mm ....................................... 0.823 mm²
"SAVE THESE INSTRUCTIONS"