INSTALLATION
4

FINAL PREPARATION

Connections and checks
F
< 400N in spaces between 50mm and 500mm
d
F
< 1400N in spaces> 500mm
d

User instruction

1 Instruct the user with regards to the use and
maintenance of the facility and provide him/her with
the use manual.
50
Installation manual
1 Carry out the installation and the connections for all
the elements of the facility, in line with the control
panel instructions.
Except in VUS models (which have a patented
obstacle detection), it is necessary to install
additional protection devices in order to fulfil
the requirements of standard EN 12453:2017.
2 Check that the mechanism is correctly regulated.
The opening and closing forces must be
adjusted to respect the values indicated in
standard EN 12453:2017, as shown in the
attached chart. The measurements must be
made in line with the method described in
standard EN 12453:2017.
For models without a patented safety device,
the gate should not exercise a force in excess of
150N (15kg).
3 Check the operation of all the installation elements,
especially the protection systems and the manual
operation unlocking system.
2 Point to the gate, showing that it opens
automatically, and indicating how to operate it
manually.
Where
appropriate,
operation is using the remote control.
indicate
that