4. 3-Wire Power Cord Installation
WARNING:
The neutral or ground wire
of the power cord must be connected to the neutral
terminal located in the center of the connector block.
The power leads must be connected to the outside
(brass colored) terminals.
Remove the 3 wire terminal screws from the connector
block, Insert screws through each power cord terminal
ring and into the connector block until the screws
engage the nuts, Be certain that the center wire is
connected to the center screw of the connector block.
Tighten screws securely,
Do NOT remove ground strap connection.
Connector blbck
5. 4-Wire Power Cord Installation
WARNING:
The neutral wire of the
supply circuit is connected to the neutral terminal
located in the center of the connector block. The
power leads must be connected to the outside (brass
colored) terminals. The 4th grounding lead must be
connected to the frame of the range with the
grounding plate and grounding screw.
a. Remove the 3 screws from the connector block,
b_
C.
Remove the grounding screw and strap from the
connector block middle location and the screw
connection to the frame of the range,
Insert screws through each power cord terminal ring
and into connector block until screw engages nut,
Be certain that the center wire is connected
to the center screw of the connector block,
Tighten screws securely.
d. Attach ground wire to the frame of the range,,
Ground strap
Before
Neutral terminal
_ound
Strap
(grounding
to range)
After
Neutral
termlnaD
.._I'_"
_
Grounding
Grounding to range