6. 3-Wire Conduit Installation
Remove the 3 screws from the connector block, Insert
bare wires between the connector block terminals and
movable nuts, Tighten screws securely, Do not remove
ground strap connection°
WAR NING: Connector
block iS
approved
for copper wire connection only. if aluminum
wire is used, see note below.
NOTE: ALUMINUM WIRING
a.
b_
Do not connect aluminum wire to connector block.
Use copper building wire rated for the correct
amperage and voltage to make 3 (three) 3 copper
jumper wires, Connect wire as per Step 6 or 7
depending on number of wires,
Splice copper wires to aluminum wiring using special
connector terminals designed and UL-approved for
joining copper to aluminum and follow the connector
manufacturer's
recommended
procedure closely.
Wire used, location
and enclosure of splices,
etc., must conform to good wiring practices
and local codes.
_,._
_<_
Screw
_.3i'_/-.,_P--Connector
block
terminal
Bare wire __
Movable nut__
"_-"_
I
Flexible cable
7. 4-Wire Conduit
Installation
Remove the 3 screws from the connector block_ Remove
the grounding strap from the connector block middle
location and the screw connecting it to the frame of the
range° Insert bare wires between the connector block
terminals and movable nuts° Tighten screws securely,
Attach ground wire to the frame of the range,
WARNING:
Connector block is
approved for copper wire connection only. If
aluminum wire is used, see note below.
NOTE: ALUMINUM WIRING
a.
b_
Do not connect aluminum wire to connector
block.
Use copper building wire rated for the correct
amperage and voltage to make 3 (three) 3 copper
jumper wires. Connect wire as per Step 6 or 7
depending on number of wires.
Splice copper wires to aluminum wiring using special
connector terminals designed and UL-approved for
joining copper to aluminum and follow the connector
manufacturer's
recommended
procedure closely,
Wire used, location and enclosure of splices,
etc., must conform to good wiring practices
and local codes.
Screw
Bare wire
---------_'_",_
Movable nut-.-__
I
Flexible cable
Conduit
tips
Connector
block_
Bracket _
Bare wire tips
_-_---_
Grounding
plate
-,_----
Conduit
18