ATTENTION: If, after the therapy session, an obvious deposit
of moisture forms inside the tube (B1), detach the tube from
the nebuliser and dry it with the ventilation of the compres-
sor itself; this action prevents possible mould growth inside
the tube.
To facilitate the connection of the connection tube (B1) to the
compressor unit, act on the end of it by simultaneously rotat-
ing and inserting it, and for removal by rotating and extracting
it.
WAYS OF USING THE 'RF7 DUAL SPEED PLUS' NEBULISER WITH SPEED SELECTOR AND VALVE SYSTEM
It is professional, fast and suitable for the administration of all types of drugs,
including the most expensive ones, even in patients with chronic diseases. Thanks
to the geometries of the internal ducts of the RF7 Dual Speed Plus nebuliser, a
suitable and active particle size was obtained for treatment down to the lower
respiratory tract.
To speed up inhalation therapy, position the speed selector with valve (B2.4) by
pressing the MAX marking with your finger.
To make the inhalation therapy more effective, position the speed selector with
valve (B2.4) by pressing with a finger on the side opposite the Max marking, in this
case you will obtain an optimal administration of the drug while minimising its
dispersion in the surrounding environment, thanks to the valve system with which
the ampoule, mouthpiece and mask are equipped.
SoftTouch masks
Soft
biocompatible
material
Dispersion
Limiter
Upon inhalation, the tab, which acts as
a Dispersion Limiter, bends inwards in
the mask.
USE OF MANUAL NEBULISATION CONTROL
In order to achieve continuous nebulisation, it is advisable not to apply the manual nebulisation
control (B7), especially in the case of children or care-dependent persons. The manual nebulisation
control helps limit the dispersion of the drug into the surrounding environment.
To activate nebulisation, plug the
hole of the manual nebulisation
control (B7) with a finger and
inhale gently and deeply; it is rec-
ommended that after inhaling you
hold your breath for a moment so
that the inhaled aerosol droplets
can settle,
SoftTouch masks have an outer edge made of soft, biocompatible ma-
terial that ensures an optimal fit on the face, and are also equipped with
theinnovative Dispersion Limiter. These characteristic features allow
for greater sedimentation of the drug in the patient, and again limit its
dispersion.
11
B1
A2
Upon exhalation, the tab, which acts as
a Dispersion Limiter, bends outwards
from the mask.
In the meantime, to stop nebulisa-
tion, remove your finger from the
hole of the manual nebulisation
control, thus avoiding the waste
of medication and optimising its
administration. Then exhale slowly.