INSTALLATION INSTRUCTIONS
electric power to the pump without coverplates in place. Always disconnect power
before repairing or servicing
Pump Installation
1.
Make sure all threaded fuel connections are wrapped with three to four turns
National, State, and Local codes. Including, but not limited to; NEC/CSA 22.1/ANSI/IEC/
of the supplied thread tape.
NFPA 70, 30, and 30A. You, as the owner, are responsible for seeing that the installation
2.
Make sure supply tank or container is vented. A vent cap rated at 3 psi or
and operation of your pump complies with all applicable codes. Rigid conduits must be
less is recommended.
used to install wiring. Note that the lead wires are factory-sealed, isolating the motor
NOTE: These components have not been evaluated as part of the UL Listed
from the junction box. Failure to follow these wiring instructions may result in death or
Equipment and are not intended for use in a Hazardous (Classified) Location.
serious injury from shock, fire or explosion.
Install Inlet Hose and Strainer
1.
Wrap the threads of one end of the inlet hose 3 or 4 times with thread tape
fuel tanks, trailers, etc. Connection to a battery will depend upon the application. If
(supplied).
the pump is to be installed in a Class I, Division I location please contact GPI for the
2.
Install hose end into inlet side of pump (see Figure 1) and tighten.
appropriate product.
3.
Wrap threads on other end of hose 3 or 4 times with thread tape (supplied).
4.
Install metal strainer and tighten.
NOTE: To avoid damage to pump from dirt and debris, do not operate pump
cigarette lighter wire, as improperly sized wires could overheat and cause a fire.
without strainer.
IMPORTANT: Verify switch is in OFF position, then route the electrical wires
Install Outlet Hose and Nozzle
to the source of the vehicle power system. Be sure to support the wires as
necessary and protect them from sharp edges, heat, or anything that could
1.
Wrap the threads of one end of the outlet hose 3 or 4 times with thread tape
damage the wires.
(supplied).
2.
Install hose into outlet side of pump (see Figure 2) and tighten.
3.
Wrap threads on other end of hose 3 or 4 times with thread tape (supplied).
4.
Install manual nozzle and tighten.
NOTE: To minimize static electricity build up and possible explosion, use only
static wire conductive hose when pumping flammable fluids.
5.
Keep the fill nozzle in constant contact with the container being filled during
the filling process.
EN
Coverplates protect the operator from moving parts. Never
operate the pump without coverplates in place. Never apply
If the pump is to be installed in a hazardous (classified) location,
it must be installed by a licensed electrician and conform to all
NOTE: The MU, AU, MD, and AD pumps are pre-wired for
installation in Class I, Division 2 locations such as portable
Do not attempt to power the pump from vehicle wiring smaller
than the cord gauge specified in the owners manual such as the
Sparks or static discharge will cause explosions.
1
2
3
4
5
7