6.screw nut (up)
7.Modelling cap
8.dispensing valve
d、Put the components into disinfecting solution to clean,check the beater,
gasket for beater, O-ring for dispenser door, supporting sleeve and O-ring
for piston, if they are worn oldly, they should be replaced;
e、After cleaning, lubricate the parts with vaseline, then install the parts
according to the method of taking apart.
Notice: Before installing the piston, O-ring for piston, beater and gasket for
beater, you should lubricate vaseline (lubricating vaseline onto the groove
of the gasket, do not onto the beater's end ), using the vaseline frequently
can extend the service life of components.
B、Cleaning Machine Cabinet
Keep the machine cabinet clean, use wet towel to clean the cabinet, and
do not flush the machine with water directly.
C、Cleaning Condenser
After be used over a period of time, the condenser maybe thick with dust,
and this will effect radiate heat and cause refrigeration difference, so it
needs periodic cleaning (every half year)
Cleaning methods:
Step 1: Disconnected the main power switch.
Step 2: Remove the back panel and side panels.
14.gasket for beater
15.New design middle piston O-ring
16.New design middle piston
Fig.4
- 15 -