The self-protection of
the compressor
because of overload.
The compressor broke
The capacitor of the
compressor broke
Leakage of the
refrigerant
Machine
do not
Electrical valve broke
freeze
Fan motor do not run
down
The capacitor of the fan
motor broke
The set point is too low
There is some problem
Machine
with control panel.
non-stop
Refrigeration difference
Low voltage
The relay
There is some problem
is not
with control panel.
stable
The touch point of the
contact switch broke.
The proportion of mix is
incorrect, and causes
the refrigeration
difference
Product
No mix in the hopper
does not
dispenser
Limit switch broke or the
tie wire is unfastened.
The belt is unfasten or
skid around
Find and solve the problem
Change the compressor
Change the capacitor
Find and repair the leak in the
pipe, then vacuum and recharge
the refrigerant
Change the electrical valve
Repair or change the fan motor
Chang the capacitor of fan motor
Increase the set point
Change the control panel
Check and repair the refrigerating
system
Solve the problem of low voltage
Change the control panel.
Remove the touch point or
change the contact switch.
Make up a proper proportion of
mix.
Pour the mix into the hopper
Change the switch or fasten the
wire
Change or adjust the belt
- 17 -