Step 3: Clean dust with tools such as vacuum cleaner, high-pressure air
and hairbrush, be careful while cleaning to avoid damaging the fins of the
condenser.
D、Belt Adjustment
After be used over a period of time, the belt of the machine maybe
elongated, so it needs to be adjusted. Disconnected the main power of the
machine, remove the back panel and side panels, adjust the tension bolt
and make sure the belt is in appropriate tension.
V.Trouble shooting guide
Problems
Machine not plugged
into the wall receptacle
Machine
does not
The short-circuiting
run
switch is open
Protect circuit
The connecting wire is
Machine
unfastened
in clean
position
The beater motor broke
does not
Mini circuit breaker was
run
broken.
Machine
The wire of function
in auto
switch is unfastened.
position
There is some problem
does not
with control panel.
run
Low voltage
Contactor broke
Compress
The relay of the
or does
compressor broke
not run
There is some problem
with control panel.
Probable cause
Plug machine in
Restart it after it was repositioned
Remove the trouble
Check and fasten the wire.
Repair or change the beater
motor
Find and solve the problem then
reposition it
Check and fasten the wire.
Change the control panel.
Solve the problem of low voltage
change contactor
Change the control panel.
Change the control panel.
- 16 -