Exploded View
Vue éclatée / Explosionszeichnung / Vista esplosa
Explosietekening / Sprängvy / Vista explotada
4
Spare Parts List
(A)
Pump Head Kit (NPT)
Pump Head Kit (BSP)
(B)
Seal Kit
(C)
Motor Kit (12V)
Motor Kit (24V)
KEY
DESCRIPTION
1
Housing
2
End Cover
3
O-Ring
4
Screws
5
Impeller
6
Seal
7
Motor
8
Locking Nut
9
Slinger
WARNING: Motor may get hot after prolonged
use, do not touch. Burns may occur.
Wire Size Table
Model
Voltage
Number
50840-XX12
50840-XX24
* Wire length from battery to pump and back to battery, maximum voltage drop 3%
3
5
8
2
50844-0000
50844-2000
50835-0000
50836-0012
50836-0024
KIT KEY
A
B
C
1
1
1
1
5
5
1
1
1
1
1
1
Maximum
Current
12V
9.0 A
24V
4.5 A
7
9
1
6
Wiring Instructions
• All electrical wiring should be connected and installed by a
competent electrician. A qualified person must ensure that the
installation conforms to the regulations in place.
• Ensure connections are of the correct polarity red/orange (+ve)
black negative (-ve). Note; if wired in reverse the pump will
still run but give poor performance.
• Always use the correctly rated fuse or circuit breaker. If a circuit
QTY
breaker is used it should be of the "conditionally surge current
proof" type.
PER
KIT
• Check that the supply voltage is compatible with the voltage
specified on the label. A discharged battery will result in
1
reduced pump performance.
1
Overload
Protected
1
Distribution
Panel
5
1
1
1
1
1
Battery
WARNING: If the fuse fails repeatedly, do not
fit a heavier fuse or bridge the terminals. Fire and
death may occur.
Fuse
Size
10 A
7 A
3
Wiring Diagram
Orange
Black
Inlet port
Wiring Size*
AWG
mm²
14
2.5
10
6.0
18
1.0
16
1.5
Fuse
Outlet
port
Max. Length
15 ft (4.5m)
30 ft (9.0m)
15 ft (4.5m)