setting.
Press
button again, temperature flash, press
setting.
button to confirm timer ① off, and it will jump to timer ② page.
Press
If don't need to set timer ② and ③, press
Do the same above to set timer ② and timer ③.
From home page, press
4.2.5 To set time
Press
button for 3s to enter time setting page, hour flash, press
hour setting.
Then press
button, minutes flash, press
Then press
button to confirm.
4.2.6 Speaker
When switch on the power supply the speaker will make noise.
When short press button the speaker will make noise.
When long press button the speaker will not make noise.
4.2.7. Special cycle
1) Anti-legionella cycle
When the anti-legionella function is activated, it show H1 on in the temperature display zone
(always bright), clock zone shows current temperature of water tank.
After connected with power, to prevent bacteria from growing in the water in the tank, if the
water temperature is not up to 70℃ in a certain period(168h), it will be heated to 70℃ once.
Note: Anti-legionella cycle can be activated or deactivated on control panel, default is deactivated,
refer to configuring parameters table.
2) Anti-freeze cycle
When the anti-freeze function is activated, it show H2 on in the temperature display zone (always
bright), clock zone shows current temperature of water tank.
If detect ambient air≤5℃ when heat pump is standby, heat pump will heating automatically to
keep tank water between 20℃-28℃.
Note: Anti-freeze cycle can be activated or deactivated on control panel, default is activated, refer to
configuring parameters table.
3) Photovoltaic cycle
When heat pump is running with photovoltaic power, it show H4 on in the temperature display
zone (always bright), clock zone shows current temperature of water tank.
button for 3s to save and exit.
button, then press
or
18
or
button to adjust water temperature
button again for 3s to cancel all timers.
or
button to adjust hour setting.
button to adjust