Mount the magnetic limit switches
4
ELECTRICAL CONNECTIONS
Complete the installation in line with low voltage regulations and applicable rules.
Use cables with sufficient section, always earthed.
Check the manufacturer's instructions for all the elements installed.
1 Move the gate manually to the opening position,
and position the opening magnet (1) with the
respective magnet-holder plate (2).
In the gate open position, the magnet (1) must
be opposite the magnetic opening limit switch (Hall
effect sensor) (3).
O
Distance between the magnets and the
operator frame: 10 mm at most.
2 Move the gate manually to the closing position, and
position the closing magnet (4) with the respective
magnet-holder plate (5).
In the gate closed position, the magnet (4) must
be opposite the magnetic closing limit switch (Hall
effect sensor) (6).
O
Distance between the magnets and the
operator frame: 10 mm at most.
3 Lock the operator using the handle (7).
INSTALLATION
PUMA operator for sliding gates
39