Idiomas disponibles

Care and cleanin
of the water heater.
Cleaning the Filter
In the Hybrid, Heat Pump and High Demand/Boost modes, the
heater moves air through the system and out the back of the
unit. The filter is in place to protect the evaporator from dirt and
dust.
A clean air filter is important to get the highest efficiency.
Occasionally this filter will need to be cleaned (minimum once per
year). When the filter requires cleaning, the Red light above the
Filter button will be illuminated and an audible beep will sound.
NOTE:If the filter gets too dirty, the unit will automatically switch
to Electric/Standard mode and energy savings will be lost.
Leavethe power on. Removethe filter from
the top of the unit. Squeezetwo tabs and lift to remove the air
filter. Once it has been removed, the filter can be vacuumed or
wiped clean with a damp cloth or rinsed with warm water.
Once the filter has been cleaned and dried, it can be replaced by
aligning it into the slots in the top of the unit and pushing it down
into place.
After the clean filter has been reinstalled, press and hold the
FILTERbutton. If a heating cycle is on when the filter fault is
reset, it will continue in electric mode to finish the cycle. After
that, it will automatically revert to the mode it was in prior to
being switched.
IMPORTANT:Filter must be cleaned when the alarm is displayed.
A dirty filter will make the system work harder and result in a
reduction of efficiency and possible damage to the system. In
order to get the best energy efficiency available, make sure your
filter is clean.
Tabs
Filter
Clearing the Condensation Drain Tube
The main drain is intended to carry all condensate away. If it is
clogged, the heat pump will stop operating, the display will show
F20,and an alarm will sound. Pressany button to silence the
alarm, then clear the condensate drain by removing any drain
lines and connections, and clearing debris. Reattach drain lines
and connections, then allow the water heater to run.
Periodically inspect the drain lines and clear any debris that may
have collected in the lines.