Product Specifications
Engine Specifications
Displacement
Spark Plug Part No.
Spark Plug Gap
Gasoline Capacity
Oil Type
Oil Capacity
Run Time at 25% / 50% Load
* Go to
www.powermate.com
Hour Meter
The Hour Meter tracks hours of operation for
scheduled maintenance. See
• The CHG OIL display will illuminate every
100 hours. The message will flash one hour
before and one hour after each 100 hour
interval, providing a two hour window to
perform service.
• The SVC display will illuminate every 100
hours. The message will flash one hour
before and one hour after each 200 hour
interval providing a two hour window to per-
form service.
When the hour meter is in flash alert mode,
the maintenance message will alternate with
elapsed time in hours and tenths. The hours
will flash four times, then alternate with the
maintenance message four times until the
meter automatically resets.
• 100 hours - CHG OIL — Oil Change Inter-
val (Every 100 hrs)
• 200 hours - SVC — Service Air Filter
(Every 200 hrs)
NOTE: The hour glass icon will flash when the
engine is running. This signifies the meter is
recording hours of operation.
0000.0
Figure 2-6. Hour Meter
Owner's Manual for Portable Generator
PM3800
212 cc
See Chart in
17 / 14 Hours
or contact an IASD for replacement parts.
Figure
2-6.
000205
PM4500
0J00620106
0.028-0.031 inch or (0.70-0.80 mm)
18.9 L (5 gal)
Add Engine Oil
0.6 L (.63 qt.)
16 / 12.5 Hours
Connection Plugs
120 VAC, 20 Amp, Duplex
Receptacle (if equipped)
The 120 Volt outlet is overload protected by a
20 Amp push-to-reset circuit breaker. See
ure
2-7. Each receptacle will power 120 Volt
AC, single phase, 60 Hz electrical loads
requiring up to 2400 watts (2.4 kW) or 20
Amps of current. Use only high quality, well-
insulated, 3-wire grounded cord sets rated for
125 Volts at 20 Amps (or greater).
Figure 2-7. 120 VAC, 20 Amp, Duplex
Receptacle NEMA 5-20R
120 VAC, 20 Amp, GFCI Duplex
Receptacle (if equipped)
The 120 Volt outlet is overload protected by a
20 Amp push-to-reset circuit breaker. See
ure
2-8. Each receptacle will power 120 Volt
AC, single phase, 60 Hz electrical loads
requiring up to 2400 watts (2.4 kW) or 20
Amps of current. Use only high quality, well-
insulated, 3-wire grounded cord sets rated for
125 Volts at 20 Amps (or greater). It also pro-
vides protection with a Ground Fault Circuit
Interrupter with a press to TEST and RESET
button.
PM4400E
224 cc
16 / 13 Hours
000424
Fig-
Fig-