Description of air heater
LHS 210/410 SF (HT) DF (HT)
2
7
1. Threaded holes for device mounting
2. Connection housing cover
3. Screws for connection housing cover
4. Cable gland for mains connection (factory fitted)
Preparation
Remove the LHS air heater from the packaging.
Loosen the screws (3) to remove the cover of the connection housing (2).
Remove the warning note, read carefully and keep it for further reference.
Assemble the connection cable.
Pull the connection cable through the cable gland (4).
Connect the connection cable to the connection pins. as per the "Wiring Diagram" section.
Check connections for secure screw connection.
Attach the cover for the connection housing (2) using the screws (3). Retighten cable through the cable
gland (4).
Tighten the cable gland (4).
Installation
The installation must ensure that:
- the locally applicable standards and laws are observed.
- the supplied air conforms to the specifications under the chapter "Technical data".
- no (heat) backflow occurs.
- the air heater is not flowed by the hot air jet of another device.
- the air heater is protected against mechanical vibrations and vibrations.
- the air heater is attached to the threaded holes for the device assembly (1)
(For installation dimensions see pages 3-4)
- the connection housing of the air heater is not damaged by backflowing hot air.
16
4
3
Air flow
5
6
1
8
LHS 210/410 SF-R (HT) DF-R (HT)
2
9
7
8
5. Heating tube
6. Screws for heating tube
7. Injection opening
8. Threaded holes for blow-in spigot mounting
9. Thermal bridge pipe
4
3
Air flow
5
6
1