EN | Set up
Set up
Risk of injury from RFID
DANGER
sensor for persons with
pacemakers or defibrilla-
tors
If you wear a pacemaker, keep a distance of at least
24 in from the RFID sensor on the front panel.
If you wear a defibrillator, keep a distance of at least
16 in from the RFID sensor on the front panel.
A test in accordance with DIN VDE 0100 or the
applicable national regulations must be carried out
during initial commissioning and at the prescribed
maintenance intervals.
Information
The meter reading of the integrated electricity meter
is not 0 kWh for production reasons.
Configure the service
Faulty Wallbox
CAUTION
A Wallbox with an active fault is not fully functional.
There is an active fault if the LED
state is lit red.
Information
The service should be configured without a vehicle
connected.
The Wallbox is switched on as soon as it is powered.
e
Switching on the Wallbox
The LEDs are lit one by one.
38
Fig. 19: Design front of the control unit
1
Backend indicator light
2
Authorisation indicator light
3
Brightness sensor
4
Power switch
Display
for the operating
White
Flashing white
Green
Flashing green
Display
Flashing blue
Orange
Flashing orange
Red
White
Green (2 -
4 secs)
Flashing red (2 -
4 secs)
Meaning
Wallbox is switched on and
Red
ready for operation
Connecting
White
Charging complete
Flashing blue
Charging vehicle
Meaning
Charging paused (ISO)
Restart Wallbox
Wallbox starts
Charging error
Authentication required
Authentication successful
Authentication failed
Module error
Back-end connection failed
Wallbox is reset to factory
settings