en-us Conversion to LP gas
Flame characteristics
The color of the flame tells you if the gas supply is properly adjusted.
Note: Allow the appliance to operate for 4 to 5 minutes before evaluating the flame. Some yellow streaking is normal
during the initial startup.
Flame
Image
Completely or mostly
yellow
Yellow tips on outer
cone
Soft blue
5 Conversion to LP gas
Conversion to LP gas
Your appliance is equipped for use with natural gas on
Conversion to LP gas
delivery. It can be converted to LP gas supply.
The components required for conversion to LP gas are
contained in the LP conversion kit included with this
appliance, or are available from Customer Service.
→ "Customer Service", Page 16
Only a qualified technician or installer is authorized to
convert the appliance to another gas type.
Before carrying out the conversion, turn off the electricity
and gas supply.
5.1 Converting the pressure regulator
WARNING
Turn off the electricity and gas supply before carrying out
the conversion.
Locate the pressure regulator on the bottom right end of
1.
the appliance.
14
Measure
Verify that the regulator is set for the correct fuel. Retest
after adjustment.
Normal for LP gas
Normal for natural gas
Remove the hexagon shaped conversion cap from the
2.
regulator. Make sure not to dislodge the gasket
the cap or the spring
inside the regulator.
on