Descargar Imprimir esta página

Angelo Po 2N1FAGF Manual De Uso página 180

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

ENGLISH
HAZARD: Before doing any work, cut
off the mains electricity supply.
Undo the screws (A) and remove the control
1)
panel (B).
Modify the connections of the terminal bo-
2)
ard (C) as shown in the diagram and in the
electrical system diagram at the back of the
manual.
Replace the control panel (B) on completion
3)
of the operation.
Remove the test voltage indicator sticker
4)
from the dataplate and apply the new one to
identify the voltage being used.
NOTA: On completion of the operation
make sure that there are no malfunctions.
WARNING: Before it is put into ser-
vice, the system must be tested to check the
operating conditions of every single compo-
nent and identify any malfunctions. In this
stage, it is important to check that all health
and safety requirements have been com-
plied with in full.
To test the system, make the following checks:
Check that the mains voltage is the same as
1)
that of the appliance
Operate the appliance's circuit-breaker to
2)
check the electrical connection.
Turn on the gas supply tap and check that
3)
the connections are right.
Check that the mains gas is the same as that
4)
used for commissioning of the appliance,
and carry out the conversion procedure if
necessary (see page 12).
14
TESTING OF THE APPLIANCE
5)
6)
7)
8)
9)
After testing, if necessary instruct the user in all
the skills necessary for putting the appliance
into operation in conditions of safety, in ac-
cordance with legal requirements.
HANDLING AND INSTALLATION
B
A
C
Check that the top and oven burners are
lighting correctly and their combustion.
Check the gas pressure and fl ow-rate at mini-
mum and maximum settings and adjust if
necessary (see page 7).
Check that the safety device is operating cor-
rectly.
Check that there are no gas leaks.
Check that the nameplates specify the cor-
rect gas for the country of use.
3301360_inst_GB_rev.2
C

Publicidad

loading

Este manual también es adecuado para:

2t1fagf