observe the applicable regulations for the disposal of
such waste.
– Clean the maintenance area after completing the work.
Cleaning the Filters
Regularly emptying the dust container and cleaning the fil-
ters will ensure optimum suction power. If suction power is
not achieved after that, the vacuum cleaner is to be brought
to the after-sales service.
Removing/changing the filter (see figures H1–H2)
Replace the damaged pleated filter immediately.
– Turn the filter holder (29) as far as possible in the direc-
tion of rotation
and take the filter holder, together with
the main filter (19), out of the top part of the vacuum
cleaner (7).
– Take the dirty/damaged main filter (19) out of the filter
holder (29).
– Brush the folds of the main filter (19) with a soft brush.
or
Replace the main filter (19) if damaged.
– Place the filter holder (29) on the cleaned/new main filter
(19).
– Place the filter holder (29), together with the main
filter (19), over the filter basket (30) and turn the filter
Rectifying faults
If a fault (e.g. a filter damage) occurs, the vacuum
u
cleaner must be switched off immediately. The fault
must be repaired before resuming operation.
Problem
Suction turbine will not switch on.
The suction turbine will not switch on
again after the container has been
emptied.
The suction power is decreasing.
Dust is escaping during extraction
Automatic switch-off (wet extraction)
is not working.
The filter cleaning function is not
working.
Bosch Power Tools
holder (29) as far as possible in the direction of rotation
.
– Put the top part of the vacuum cleaner (7) on and close
the catches (8).
– Open the catches (8) and remove the top part of the va-
cuum cleaner (7).
Cleaning the container
Wipe the container (1) from time to time using a non-abras-
ive off-the-shelf cleaning product and leave it to dry.
Storage and transport (see figure I)
– Wrap the power cable around the carrying handle (5).
– Place the suction tubes (25) in the holders (11).
– Place the vacuum hose (16) around the top part of the va-
cuum cleaner and hang the retaining strap (15) on the
holder (10).
– Carry the vacuum cleaner by the carrying handle (5).
– Store the dust extractor in a dry room and secure it so
that it cannot be used by unauthorised persons.
– Put the castor brake (13) down to hold the castors (9) in
place.
Corrective measure
– Check the mains cable, mains plug, fuse and socket.
GAS 15 PS:
The mode selector switch (4) is set to "automatic start/stop".
– Set the mode selector switch (4) to the "extraction" symbol or switch on the
power tool plugged into the plug socket (3).
– Switch the dust extractor off and wait 5 seconds before switching it back on.
– Empty the container (1).
– Remove any blockages from the vacuum nozzle, suction tube (25), vacuum hose
(16) or filter (19).
– Change the plastic bag (18) or dust bag.
– Make sure the filter holder (29) is engaged correctly.
– Place the top part of the dust extractor (7) on correctly and close the catches (8).
– Change the main filter (19).
– Check that the main filter (19) has been fitted correctly.
– Change the main filter (19).
Automatic switch-off will not work in the presence of non-conductive liquids or foam-
ing.
– Check the fill level regularly.
– Press the SFC switch (6).