3. TECHNICAL DATA
Model
Mains voltage / Frequency
(V / Hz)
Nominal performance (Watts)
Protection type (IP)
Suction port
Pressure port
Max. flow rate (Qmax)
(l/h)
(1)
Max. pressure (bar)
Max. delivery height
(Hmax)
(m)
(1)
Max. suction height (m)
Max. size of the solids being
pumped (mm)
Max. ambient temperature (°C)
Max. fluid temperature
(Tmax) (°C)
Length of connection cable (m)
Cable type
Weight (net) (kg)
Guaranteed sound power level
(LWA)
(dB)
(2)
Measured sound power level
(LWA)
(dB)
(2)
Sound pressure level (LpA)
(2)
(dB)
Dimensions (L x D x H) (mm)
Item n
.
o
1) The values were determined with free, unreduced in- an
outlet.
2) Noise emission values obtained according to the EN
12639 regulation. Measurement method according to
EN ISO 3744.
4. SCOPE OF DELIVERY
The scope of delivery includes a suction hose, an
intake filter with a check (or non-return) valve, a
pistol-type fuel nozzle (without automatic stop
feature), connection pieces, hose clamps and
sealing rings.
5. INSTALLATION
5.1. GENERAL INSTALLATION INFORMATION
SPIDO TR50
230/50
550
being discharged. If this venting requirement is not
IPX4
observed, the pump will not take in the liquid being
discharged.
F26/34 (1")
F26/34 (1")
2 100
3,5
35
5
connection system has to be protected from frost
0
and weather influence.
40
40
1.5
H07RN-F
10.8
the vapours. Ensure sufficient ventilation. Please
wipe off any spilled diesel fuel, fuel oil or rapeseed oil
68
completely.
All connection lines have to be perfectly tight since
61.4
leaking lines will affect the performance of the pump
and may even cause considerable damage. Please
56.1
use appropriate sealing material to ensure an airtight
installation. The use of PTFE tape or comparable
260 x 100 x 190
sealing material is to be avoided since it will be
002650
destroyed by diesel fuel, fuel oil and rapeseed oil.
When tightening threaded connections, please
do not apply excessive force which may cause
damage. When laying the connection pipes, you
should make sure that the pump is not exposed to
any form of weight, vibration or tension. Moreover,
the connection lines must not contain any kinks or
an adverse slope.
The scope of delivery includes one intake line (2)
and one pressure line (11) which were specifically
designed for the type of fluid to be discharged
using the present pump. The lengths of the hoses
initially coming with the pump are different. For most
applications, the shorter hose should be used as a
suction hose, whereas the longer hose should serve
as a pressure line.
If you are using hoses other than those initially
coming with the pump, please do make sure that
they are suitable for pumping the specific liquid to be
discharged. Also, the intake or pressure line should
have the same diameter as the suction port (1) or
pressure port (2) of the pump.
When installing the unit, please make sure
that the pump housing and the intake line
are fully vented, i.e. filled with the liquid
During the entire process of installation, the
device must not be connected to the
electrical mains.
The pump is to be set up in a dry location,
with the ambient temperature not to exceed
40°C. The pump including the entire
When installing the device, please make
sure that the motor is sufficiently ventilated.
When handling diesel fuel or fuel oil,
smoking is not allowed, and open fire is to
be kept off the site. Please avoid inhaling
GB