Variable modbus
Address
Display label
App
type
16432
AbPd
BOOL
16433
dPOn
USINT
16434
dPS
USINT
16435
dPA
USINT
16478
PP2
INT
16484
t2P
INT
16440
AbrA
USINT
16437
FUA
BOOL
16388
Ud4E
BOOL
16442
dLP
USINT
16443
dLE
USINT
16475
LEDP
BOOL
16444
ddP
USINT
16418
dE1
UINT
16459
Arq
BOOL
16462
FdP
USINT
16453
S1F1
INT
16454
S2F1
INT
16455
S1F2
INT
16456
S2F2
INT
16457
S1F3
INT
16458
S2F3
INT
16463
FSMi
INT
16464
FSMA
INT
16480
ABO
BOOL
16481
DOI
USINT
9205
C1H
UINT
9206
C1HL
UINT
9207
C2H
UINT
9208
C2HL
UINT
9209
UPH
UINT
9210
UPHL
UINT
9230
H2OR
BOOL
9231
HPS1
BOOL
9232
HPS2
BOOL
9233
PMPT
BOOL
9234
HTC1
BOOL
9235
HTC2
BOOL
9236
PHAS
BOOL
9237
LH2O
BOOL
9238
ONOF
BOOL
9239
LPS1
BOOL
9240
LPS2
BOOL
9241
ALRM
BOOL
9242
UAL1
BOOL
9243
UAL2
BOOL
9244
CMP1
BOOL
9245
CMP2
BOOL
9246
FAN1
BOOL
9247
FAN2
BOOL
Default
Min
Max
Unit
TRUE(1)
FALSE(0)
TRUE(1)
15
dLE
60
Sec
5
0
60
Sec
5
0
60
Sec
0
0
3
30
1
72
Hours
2
0
2
FALSE(0)
FALSE(0)
TRUE(1)
FALSE(0)
FALSE(0)
TRUE(1)
2
0
10
Minutes
12
0
dPon
Sec
TRUE(1)
FALSE(0)
TRUE(1)
8
0
60
Sec
0
0
600
Sec
TRUE(1)
FALSE(0)
TRUE(1)
1
0
2
160
0
300
bar
140
0
300
bar
170
0
300
bar
150
0
300
bar
185
0
300
bar
165
0
300
bar
140
0
250
bar
185
50
300
bar
FALSE(0)
FALSE(0)
TRUE(1)
120
10
600
sec
Hours
kHours
Hours
KHours
Hours
kHours
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Read Only
Read&write Enable delay switching on pump
Read&write Delay switching ON pump (sec) at power on
Read&write Delay switching off pump (sec)
Read&write Delay switching ON pump (sec)
Read&write Enable dubble pump 0=single pump; 1=automatic double pump; 2=manual pump1; 3=ma-
nual pump2
Read&write Time switch pump with PP2=1
Read&write Start working mode of antifreeze resistor
Read&write Antifreeze resistor
Read&write Enable antifreeze resistor 0=disabled
Read&write Delay low pressure alarm
Read&write Delay water tank empy (sec)
Read&write H2O alarm selection 0=level 1=differential
Read&write Delay alarm water pressure switch
Read&write Low temperature alarm delay (seconds)
Read&write Enable control panel heater TRUE=SRQL FALSE=SRQH
Read&write Fan disable parameter 0=No effect on fan, 1=FAN3 OFF, 2=FAN 2 and FAN3 OFF;
Read&write Set 1 fan 1
Read&write Set 2 fan 1
Read&write Set 1 fan 2
Read&write Set 2 fan 2
Read&write Set 1 fan 3
Read&write Set 2 fan 3
Read&write Fan speed control minimun set At min set fan is OFF
Read&write Fan speed control maximun set
Read&write Abilitazione Olio
Read&write Ritardo allarme olio (DIL6)
Read Only
Compressor 1 working hours
Read Only
Compressor 1 working hours (x1000)
Read Only
Compressor 2 working hours
Read Only
Compressor 2 working hours (x1000)
Read Only
Unit partial working hours
Read Only
Unit partial working hours (x1000)
Read Only
H2O water request
Read Only
High pressure switch 1
Read Only
High pressure switch 2
Read Only
Pump termal protection
Read Only
High temperature switch compressor 1
Read Only
High temperature switch compressor 2
Read Only
Phase monitor
Read Only
Low H2O level
Read Only
Remote On Off
Read Only
Low pressure compressor 1
Read Only
Low pressure compressor 2
Read Only
Output alarm relay
Read Only
Output valve 1
Read Only
Output valve 2
Read Only
Compressor 1 output
Read Only
Compressor 2 output
Read Only
Output FAN 1
Read Only
Output FAN 2
ICEP080E-ICEP120E
Note
14