ERROR CODES
E01
Possible cable fault
E02
Burst clash
E03
No speed sensor signal
E05
Possible motor overload
E08
Burned control board
Do not hesitate to get touch with the Technical Assistance Service if you have any
queries by phoning customer services (see last page in manual).
Connect the wire between top controller and
bottom controller well.
a.- Check motor wires.
b.- Check that the control board is not burned
(strong smell or smoke).
c.- Check that the voltage is correct.
Check the position or replace the speed
sensor.
a.- Lubricate the belt.
b.- Check that the motor is not burned.
c.- Check that the control board is not burned.
Change the control board.