Mechanical
∫ It is important to only use the system
for the functions for which it was de-
signed.
∫ Never stand on the roof and do not
hang on the structure.
∫ We recommend that you have your roof
covering technically inspected every
year by your installer.
∫ Clean the system at regular intervals.
∫ Small wrinkling is characteristic of the
screen fabric. Do not pull the fabric
(Screen).
∫ Never attach any additional elements
or accessories to the covering, except
for the accessories that were specially
developed by Renson.
∫ To avoid damage to your covering,
keep heat sources, such as open fires
and barbecues, at 1m from the screens
or other walls. You should open the
blades of the roof, so that smoke and
heat can escape. Please note that your
blades and the walls become greasy.
These must be cleaned afterwards to
prevent adhesion.
∫ Check that no person or an obstacle
can interrupt a moving part. Moving
parts (such as the roof blades and
screens) can be dangerous.
∫ Do not place fingers between the
blades while the roof is moving.
∫ Any changes made to the product by
the customer or installer may void the
warranty.
114
SAFETY
Electrical
∫ Disconnect the covering from the
power supply during inspection or
maintenance.
∫ Frequent successive operation can
cause the motor to overheat. The
internal thermal safety will temporarily
render the system inoperable (about 10
minutes).
Electrical specifications
BLADED ROOF
Supply voltage
Power range transformer
Power transformer
Motor voltage
Rated motor current (24V DC)
Protection class
Maximum runtime during continuous use
VERTICAL FIXSCREEN
Supply voltage
Current intensity
Power
Protection class
Maximum runtime
LED LIGHTING
Colomno led
Warm white
Pure white
UpDown led
Warm white
Pure white
RGB
Lineo led
Warm white
Pure white
HEATING
Power
Current intensity
AUDIO
Speakers
∫ Do NOT let children play with the
controls.
∫ Changes to the electrical part can only
be made after approval of the manu-
facturer.
Value
230 Volts AC, 50 Hz
0 – 2.5 Amps
100 W
24 Volts DC
3 Amps
IP 66 Dynamic
Approx. 2 minutes
230 Volts AC, 50 Hz
0,8 – 1,2 Amps (according to motor type)
170 to 270 Watts (according to motor type)
IP 44
Approx. 3 to 5 minutes
550 - 680 lm/m (120 LEDs/m)
550 - 680 lm/m (120 LEDs/m)
550 - 680 lm/m (120 LEDs/m)
550 - 680 lm/m (120 LEDs/m)
570 - 700 lm/m (60 LEDs/m)
1660 lm/m (180 LEDs/m)
1660 lm/m (180 LEDs/m)
2400 W
12 A / heat - IP 65
4 Ohms Marine Speakers - IP 65
120 W peak power
Freq: 90 Hz - 22 kHz