until you hear a "click": the fan heater starts working at 1800W and the indicator
LED lights up.
• The thermostat maintains the required ambient temperature by automatically
turning the heater on and off. The more the knob is turned clockwise to a higher
number, the higher the ambient temperature will be. The highest position of the
thermostat corresponds to approximately 35°C, the bottom one (*) to about 5°C.
Using the thermostat
• In a room with a temperature in excess of 35°C, the thermostat does not turn on
the fan heater even if it is at maximum.
• Vice-versa, in a room with a very low temperature (below 5°C), the thermostat
keeps the heater constantly on, even if it is at minimum.
• To optimise use of the thermostat, proceed as follows:
- Turn the thermostat knob to maximum and wait until a comfortable tempera-
ture is reached;
- Then turn the thermostat knob anti-clockwise until you hear a "click" and the
heater turns off;
- Turn the thermostat knob clockwise just a little;
- In this position, the thermostat will maintain the selected ambient temperature.
Model with thermostat and 60' timer
• This model of fan heater is fitted with two knobs, one for the 60' timer and the
other for the thermostat.
• 2 different operating modes are available:
- Maintenance of ambient temperature:
Starting from the anti-freeze position " ", turn the thermostat knob clockwise
until you hear a "click": the fan heater starts working at 1000W and the indica-
tor LED lights up.
The thermostat maintains the required ambient temperature by automatically
turning the heater on and off. The more the knob is turned clockwise to a high-
er number, the higher the ambient temperature will be. The highest position
of the thermostat corresponds to approximately 35°C, the bottom one (*) to
about 5°C.
To adjust the thermostat, see the USING THE THERMOSTAT section above.
- Rapid heating:
Adjust the ambient thermostat to the required temperature and then turn the
timer knob to select the required operating time. The product rapidly heats the
room 1800W for the set time and then reduces power to 1000W to maintain
the ambient temperature selected with the thermostat.