English
Noise Information
Noise characteristic values in accordance with EN60745:
The typical A-weighted single-event sound power level
The typical A-weighted single-event emission sound
pressure level at work station
Uncertainty KpA: 3 dB
These values are tool-related characteristic values and do
not represent the noise development at the point of use.
Noise development at the point of use will for example
depend on the working enviro nment, the workpiece, the
workpiece support and the number of driving operations,
etc.
Depending on the conditions at the workplace and the
form of the workpiece, individual noise attenuation
measures may need to be carried out, such as placing
workpieces on sound-damping supports, preventing
workpiece vibration by means of clamping or covering, etc.
In special cases it is necessary to wear hearing protection
equipment.
Vibration Information
The typical vibration characteristic value in accordance
with EN60745: 1.7 m/s
2
Uncertainty K: 1.5 m/s
2
This values is a tool-related characteristic value and does
not represent the influence to the hand-arm-system when
using the tool. An influence to the hand-arm-system when
using the tool will for example depend on the gripping
force, the contact pressure force, the working direction,
the adjustment of energy supply, the workpiece, the
wrokpiece support.
The declared vibration total value has been measured in
accordance with a standard test method and may be used
for comparing one tool with another.
It may also be used in a preliminary assessment of
exposure.
WARNING
○ The vibration emission during actual use of the power
tool can differ from the declared total value depending
on the ways in which the tool is used.
○ Identify safety measures to protect the operator that are
based on an estimation of exposure in the actual
conditions of use (taking account of all parts of the
operating cycle such as the times when the tool is
switched off and when it is running idle in addition to the
trigger time).
NOTE
Due to HiKOKI's continuing program of research and
development, the specifications herein are subject to
change without prior notice.
LWA,1s,d = 78 dB
LpA,1s,d = 67 dB