Maintenance Schedule
Follow the maintenance schedule in table below. The maintenance frequency should be increased if
the generator is running in a dusty or other harsh environment.
Contact a DJI-authorized dealer or DJI Support to perform the maintenance items marked with an
asterisk. For any other maintenance items not covered by this document, contact a DJI-authorized
dealer or DJI Support.
Item
Level check
Engine Oil
Replacement*
Check/Cleaning
Air Filter Sponge Filter
Element
Replacement*
Check/Cleaning
Air Filter Paper Filter
Element
Replacement*
Spark Arrestor
Cleaning
Spark Plug
Check/Cleaning/
(Model: F6RTC)
Replacement*
Valve Clearance
Adjustment*
Fuel Injector Nozzle
Cleaning/
Filter, Fuel Pump
Replacement*
Fuel Filter
Replacement*
Fuel Pipe
Replacement*
• A maintenance interval of every 300 operating hours/1 year means the user should perform
maintenance based on which scenario occurs first.
• After each 300 operating hours users should contact a DJI-authorized dealer or DJI Support to
check and clean the fuel injector nozzle filter, and drain the fuel inside the high-pressure oil
pipe and the fuel pump.
• Visually inspect the fuel filter each time before use. Contact a DJI-authorized dealer or DJI
Support to replace the fuel filter if the fuel filter element inside turns black.
• Engine oil consumption increases if using the generator in high temperature environments.
Fill up the engine oil to the rated level before each use and shorten the interval of replacing
the engine oil.
Checking the Engine Oil Level
1. Stop the generator and place it on a flat surface.
2. Unscrew the dipstick and wipe it out with a clean
cloth.
3. Insert the dipstick as shown without screwing it
in. Take the dipstick out and check the oil level.
4. Add the recommended type of engine oil to the
upper limit position if its level is near or below the
lower limit mark. DO NOT add too much engine oil. Otherwise, the oil may spill.
5. Install the dipstick and tighten it.
• Damage to the generator caused by running with a low engine oil level is not covered by
warranty.
• Damage to the engine resulting from failure to replace the engine oil by following the
maintenance schedule is not covered by warranty.
• Damage to the engine caused by use of non-recommended engine oil is not covered by
warranty.
Every
operation
Check
Every 10
Every 20
operating
operating
hours
hours
First Use
Every 2 years (or when necessary)
Fill Port Dipstick
Every 50
Every 100
operating
operating
hours
hours
hours/1 year
Upper Limit
Lower Limit
Every 300
operating
11