6.3. COUNTER FUNCTION
The display stores the total number of cycles* completed. To visualize the figure, with the machine
stopped and in stand-by, press the STOP button. The figure will appear on the display for a few
seconds.
Bear in mind that all machines show a minimum of 100 to 125 cycles completed for quality control
testing.
*(Cycle = complete set of movements to squeeze a piece of fruit)
6.4. CONTACT SENSOR FUNCTION
Turn off the machine at the mains.
With the machine turned off, press STOP, keep it pressed and turn the machine on at the mains; keep
it pressed for 4 seconds and the display will show four numbers.
When you have reached this point, look for the number 4104; by pressing ON you control the two digits
on the left and by pressing SELECT you control the two digits on the right; then press STOP (when
you press STOP the display will show ----) and then turn off the machine at the mains (if the machine
is not switched off, it cannot leave this screen display).
When you turn on the machine again (first you see the programme version and then the number 4104),
it will start operating when the photocell detects oranges and will continue operating until the oranges
are finished or you press STOP.
•
If it stops when the oranges have finished, you simply need to put more oranges on the ramp
to put the machine back into operation.
•
If you press STOP, the machine will stop and the oranges will remain on the ramp. To turn the
machine back on again:
-
Remove the oranges on the ramp and then put them back again or press ON.
Important: keep the lens of the photocell clean to ensure it can visualize the fruit properly (Fig. 8).
TO RETURN TO THE STANDARD OPERATING SYSTEM.
Repeat the process by entering code 1001.
6.5. STAND BY
The machine has a stand-by power-saving system which is activated automatically after 5 minutes.
When the machine is on Stand-By, the display light goes out and all the icons except the one for the
machine are disabled.
To exit this situation, press any of the three buttons on the plate.
To deactivate the Stand By, repeat the 6.4. section process by entering the code 8024.
To activate, repeat the process by entering the code 8023.
27