INSTALL THE HOOD
(Ducted Hoods Only)
Ceiling
1. Center the flue mounting bracket over the hood location and flush with the
ceiling. Secure the upper flue bracket to the wall using (2) 4mm x 38mm
mounting screws. Note: Drywall anchors may be required (not included).
2. Tighten the screws completely. Make sure that the bracket is tight against the
wall and ceiling.
3. Remove the protective plastic film covering the decorative flue and the hood at
this time.
4. Remove the grease filters by pulling down the metal latch tab and tilting filters
downward to remove.
5. Remove all internal foam fillers that support the blower assembly inside the
hood.
6. For 48" wide hood only: Attach damper / diverter to top of hood using (2) 4mm
x 8mm mounting screws.
7. Attach the damper / duct connector (8" diameter for 30" , 36" , and 42" wide hoods
and 10" diameter for 48" wide hood) using (4) 4mm x 8mm mounting screws.
Center of
installation
C
L
Upper flue mounting
bracket slots
- 12 -
Flush with
the ceiling